External Pressure channel
Channel Number | 94 |
Total Length | 6 bytes |
Channel | Data1 | Data2 | Data3 | Data4 | Checksum |
Sensor location = Data1
Default channel names are as follows but can be changed by the user as required.
Ambient_Air_Pressure 1
Oil_Pressure 2
Fuel_Pressure 3
Water_Pressure 4
Boost_Pressure 5
Scaling factor = Data2 (2's complement)
Pressure (mb) = (Data3 + Data4 * 2^8) * 10^Data2
The range on the pressure channel is 0 - 65535mb. The resolution is 1mb and the units are mb.