Call me back | My basket | Checkout | Add to email list

     You are here: Website » Knowledge base

« back to website

InstallingConfiguringAndCalibrating / InstallingTheIMU06

Installing the IMU06


Connecting to RT Products



Connecting to a CAN system

The IMU06 will require power and signal wires connecting to the 9 way d-type connector for operation. The required wiring is:

Pin 5 Gnd
Pin 7 +12v
Pin 6 CAN L
Pin 8 CAN H
    

Note: There is no termination resistor inside the IMU06. If one is not present on the system then a 120 ohm resistor should be attached across pins 6 and 8.


Connecting to other data logging systems

The IMU06 can be connected to a variety of data logging systems, using either the RS232 or the CAN interface. A timepulse output is also provided for data alignment purposes. The connections to the IMU06 are as follows:

Pin 2 RS232 TX
Pin 3 RS232 RX
Pin 5 Gnd
Pin 6 CAN L
Pin 7 +12v
Pin 8 CAN H
Pin 9 Timepulse output
    

Note: There is no termination resistor inside the IMU06. If one is not present on the system then a 120 ohm resistor should be attached across pins 6 and 8.