Call me back | My basket | Checkout | Add to email list

     You are here: Website » Knowledge base

« back to website

DASH2PROInstallation / AnalogueInputs

Analogue inputs

The DASH2 PRO is provided with four analogue input channels. A further four can be purchased as an optional extra. These are in addition to any analogue inputs provided by connection to a data logger. Typically these are used to monitor fuel level, water temperature and oil pressure, via existing sensors. If sensors are not fitted, standard sensors are available from Race Technology. The sensor outputs should be connected to the DASH2 PRO analogue input channels on Connector B, Pins 1,2,12,13, as listed in Table 1. THE MAXIMUM INPUT VOLTAGE APPLIED TO THESE CHANNELS MUST NOT EXCEED 20V! The input voltages will need scaling to display the correct readings for the physical parameters being measured. This configuration is carried out using the DASH2PRO configuration software.

Page last modified on April 29, 2019, at 07:18 AM